CuuState
SCPI Command :
MEASurement<*>:AMPTime:ARIThmetic:CUUState
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(measurement=Measurement.Default) bool[source]
# MEASurement<*>:AMPTime:ARIThmetic:CUUState value: bool = driver.measurement.ampTime.arithmetic.cuuState.get(measurement = repcap.Measurement.Default)
Enables the use of user-defined custom unit for the amplitude/time arithmetic measurement. You can set the unit with method
RsRtx.measurement.ampTime.arithmetic.cuUnit.set().- Parameters:
measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)
- Returns:
arith_custom_unt_st: OFF | ON
- set(arith_custom_unt_st: bool, measurement=Measurement.Default) None[source]
# MEASurement<*>:AMPTime:ARIThmetic:CUUState driver.measurement.ampTime.arithmetic.cuuState.set(arith_custom_unt_st = False, measurement = repcap.Measurement.Default)
Enables the use of user-defined custom unit for the amplitude/time arithmetic measurement. You can set the unit with method
RsRtx.measurement.ampTime.arithmetic.cuUnit.set().- Parameters:
arith_custom_unt_st – OFF | ON
measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)