Eincrement

SCPI Command :

MEASurement<*>:AMPTime:EINCrement
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(measurement=Measurement.Default) int[source]
# MEASurement<*>:AMPTime:EINCrement
value: int = driver.measurement.ampTime.eincrement.get(measurement = repcap.Measurement.Default)

Sets the number of edges to be skipped per measurement event for N-period measurements.

Parameters:

measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)

Returns:

period_nedge_increment: 0 to 2.14748E+9

set(period_nedge_increment: int, measurement=Measurement.Default) None[source]
# MEASurement<*>:AMPTime:EINCrement
driver.measurement.ampTime.eincrement.set(period_nedge_increment = 1, measurement = repcap.Measurement.Default)

Sets the number of edges to be skipped per measurement event for N-period measurements.

Parameters:
  • period_nedge_increment – 0 to 2.14748E+9

  • measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)