SCPI Command :

MEASurement<*>:MNOMeas
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(measurement=Measurement.Default) int[source]
# MEASurement<*>:MNOMeas
value: int = driver.measurement.mnoMeas.get(measurement = repcap.Measurement.Default)

Sets the maximum number of measurements per acquisition if repeated measurement is enabled (method RsRtx.measurement.multiple.set() is ON) .

Parameters:

measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)

Returns:

max_meas_per_acq: 2 to 1E+6

set(max_meas_per_acq: int, measurement=Measurement.Default) None[source]
# MEASurement<*>:MNOMeas
driver.measurement.mnoMeas.set(max_meas_per_acq = 1, measurement = repcap.Measurement.Default)

Sets the maximum number of measurements per acquisition if repeated measurement is enabled (method RsRtx.measurement.multiple.set() is ON) .

Parameters:
  • max_meas_per_acq – 2 to 1E+6

  • measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)