TieSlope

SCPI Command :

MEASurement<*>:JITTer:SOURce<*>:TIESlope
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(measurement=Measurement.Default, jitterSource=JitterSource.Default) Edge[source]
# MEASurement<*>:JITTer:SOURce<*>:TIESlope
value: enums.Edge = driver.measurement.jitter.source.tieSlope.get(measurement = repcap.Measurement.Default, jitterSource = repcap.JitterSource.Default)

Sets the clock and data edges that are used for measurements. Clock or data is defined by the SOURce suffix <n>. The command is available for the following measurements: time-interval error, unit interval and data rate (method RsRtx.measurement.main.set() and/or method RsRtx.measurement.additional.set() are set to measurements TIE | UINTerval | DRATe.

Parameters:
  • measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)

  • jitterSource – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Source’)

set(jitter_ties_lp: Edge, measurement=Measurement.Default, jitterSource=JitterSource.Default) None[source]
# MEASurement<*>:JITTer:SOURce<*>:TIESlope
driver.measurement.jitter.source.tieSlope.set(jitter_ties_lp = enums.Edge.EITHer, measurement = repcap.Measurement.Default, jitterSource = repcap.JitterSource.Default)

Sets the clock and data edges that are used for measurements. Clock or data is defined by the SOURce suffix <n>. The command is available for the following measurements: time-interval error, unit interval and data rate (method RsRtx.measurement.main.set() and/or method RsRtx.measurement.additional.set() are set to measurements TIE | UINTerval | DRATe.

Parameters:
  • jitter_ties_lp

    POSitive | NEGative | EITHer

    • POSitive: The positive clock slope can be used, for example, for single data rate (SDR) signals with bit start at the positive clock edge.

    • NEGative: The negative clock slope can be used, for example, for SDR signals with bit start at the negative clock edge.

    • EITHer: For clock edges, this option can be used for double data rate (DDR) signals.For data edges, it is the most common setting.

  • measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)

  • jitterSource – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Source’)