SkwRelation
SCPI Command :
MEASurement<*>:JITTer:SKWRelation
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(measurement=Measurement.Default) MeasJitterSkewRel[source]
# MEASurement<*>:JITTer:SKWRelation value: enums.MeasJitterSkewRel = driver.measurement.jitter.skwRelation.get(measurement = repcap.Measurement.Default)
Sets the edge of the second waveform relative to the first waveform. The command is available for the following measurements: skew delay and skew phase (method
RsRtx.measurement.main.set()and/or methodRsRtx.measurement.additional.set()are set to measurements SKWDelay | SKWPhase) .- Parameters:
measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)
- set(jitter_skw_relt: MeasJitterSkewRel, measurement=Measurement.Default) None[source]
# MEASurement<*>:JITTer:SKWRelation driver.measurement.jitter.skwRelation.set(jitter_skw_relt = enums.MeasJitterSkewRel.INVerse, measurement = repcap.Measurement.Default)
Sets the edge of the second waveform relative to the first waveform. The command is available for the following measurements: skew delay and skew phase (method
RsRtx.measurement.main.set()and/or methodRsRtx.measurement.additional.set()are set to measurements SKWDelay | SKWPhase) .- Parameters:
jitter_skw_relt –
MATChing | INVerse
MATChing: Measures from positive to positive edge or from negative to negative edge.
INVerse: Measures from positive to negative edge or from negative to positive edge.
measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)