Count
SCPI Command :
MEASurement<*>:SPECtrum:RESult<*>:COUNt
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(measurement=Measurement.Default, measResult=MeasResult.Default) int[source]
# MEASurement<*>:SPECtrum:RESult<*>:COUNt value: int = driver.measurement.spectrum.result.count.get(measurement = repcap.Measurement.Default, measResult = repcap.MeasResult.Default)
Sets the maximum number of measurement results that are listed in the result table. Available for peak list and harmonic search measurements (method
RsRtx.measurement.main.set()is set to PLISt or HAR) .- Parameters:
measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)
measResult – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Result’)
- set(max_no_ress: int, measurement=Measurement.Default, measResult=MeasResult.Default) None[source]
# MEASurement<*>:SPECtrum:RESult<*>:COUNt driver.measurement.spectrum.result.count.set(max_no_ress = 1, measurement = repcap.Measurement.Default, measResult = repcap.MeasResult.Default)
Sets the maximum number of measurement results that are listed in the result table. Available for peak list and harmonic search measurements (method
RsRtx.measurement.main.set()is set to PLISt or HAR) .- Parameters:
max_no_ress – 1 to 1000
measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)
measResult – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Result’)