MaxCount

SCPI Command :

MEASurement<*>:RESult:MAXCount
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(meas_type: MeasSpectrumParam, measurement=Measurement.Default) int[source]
# MEASurement<*>:RESult:MAXCount
value: int = driver.measurement.result.maxCount.get(meas_type = enums.MeasSpectrumParam.ACPower, measurement = repcap.Measurement.Default)

Defines the maximum number of peaks that are labeled in the diagram.

Parameters:
  • meas_type – Only for peaklist measurements. For other measurement, this command returns an error.

  • measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)

Returns:

number: Maximum number of peaks

set(meas_type: MeasSpectrumParam, number: int, measurement=Measurement.Default) None[source]
# MEASurement<*>:RESult:MAXCount
driver.measurement.result.maxCount.set(meas_type = enums.MeasSpectrumParam.ACPower, number = 1, measurement = repcap.Measurement.Default)

Defines the maximum number of peaks that are labeled in the diagram.

Parameters:
  • meas_type – Only for peaklist measurements. For other measurement, this command returns an error.

  • number – Maximum number of peaks

  • measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)