Lfield

SCPI Command :

TRIGger<*>:TV:LFIeld
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(trigger=Trigger.Default) TvLineField[source]
# TRIGger<*>:TV:LFIeld
value: enums.TvLineField = driver.trigger.tv.lfield.get(trigger = repcap.Trigger.Default)

The commands is only relevant for NTSC signals and sets the field in which the line number is counted.

Parameters:

trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

Returns:

line_field: FIELD1 = odd field FIELD2 = even field

set(line_field: TvLineField, trigger=Trigger.Default) None[source]
# TRIGger<*>:TV:LFIeld
driver.trigger.tv.lfield.set(line_field = enums.TvLineField.FIELD1, trigger = repcap.Trigger.Default)

The commands is only relevant for NTSC signals and sets the field in which the line number is counted.

Parameters:
  • line_field – FIELD1 = odd field FIELD2 = even field

  • trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)