Stype

SCPI Command :

TRIGger<*>:TV:CUSTom:STYPe
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(trigger=Trigger.Default) TvSyncPulseType[source]
# TRIGger<*>:TV:CUSTom:STYPe
value: enums.TvSyncPulseType = driver.trigger.tv.custom.stype.get(trigger = repcap.Trigger.Default)

Sets the type of the sync pulse. Only relevant if method RsRtx.trigger.tv.standard.set() is set to CUSTom.

Parameters:

trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

Returns:

sync_pulse_type: BILevel | TRILevel

  • BILevel: Bi-level sync pulse, usually used in SDTV signals

  • TRILevel: Tri-level sync pulse, used in HDTV signals

set(sync_pulse_type: TvSyncPulseType, trigger=Trigger.Default) None[source]
# TRIGger<*>:TV:CUSTom:STYPe
driver.trigger.tv.custom.stype.set(sync_pulse_type = enums.TvSyncPulseType.BILevel, trigger = repcap.Trigger.Default)

Sets the type of the sync pulse. Only relevant if method RsRtx.trigger.tv.standard.set() is set to CUSTom.

Parameters:
  • sync_pulse_type

    BILevel | TRILevel

    • BILevel: Bi-level sync pulse, usually used in SDTV signals

    • TRILevel: Tri-level sync pulse, used in HDTV signals

  • trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)