SignalLevel<TriggerLevel>

SCPI Command :

TRIGger<*>:CDR:EYE:SIGNallevel<*>
Commands in total: 1
Subgroups: 0
Direct child commands: 1

Repeated Capability Setting:

# Range: Nr1 .. Nr32

driver.trigger.cdr.eye.signalLevel.repcap_triggerLevel_set(repcap.TriggerLevel.Nr1)
get(trigger=Trigger.Default, triggerLevel=TriggerLevel.Default) float[source]
# TRIGger<*>:CDR:EYE:SIGNallevel<*>
value: float = driver.trigger.cdr.eye.signalLevel.get(trigger = repcap.Trigger.Default, triggerLevel = repcap.TriggerLevel.Default)

Sets the signal levels for PAM-N signals with PAM order >2.

Parameters:
  • trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

  • triggerLevel – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘SignalLevel’)

Returns:

signal_level: Numeric value

set(signal_level: float, trigger=Trigger.Default, triggerLevel=TriggerLevel.Default) None[source]
# TRIGger<*>:CDR:EYE:SIGNallevel<*>
driver.trigger.cdr.eye.signalLevel.set(signal_level = 1.0, trigger = repcap.Trigger.Default, triggerLevel = repcap.TriggerLevel.Default)

Sets the signal levels for PAM-N signals with PAM order >2.

Parameters:
  • signal_level – Numeric value

  • trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

  • triggerLevel – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘SignalLevel’)

Cloning the Group

# Create a copy of the original group, that exists independently
signalLevel_copy = driver.trigger.cdr.eye.signalLevel.clone()