Doperator

SCPI Command :

TRIGger<*>:USBThree:FRAMe<*>:FLD<*>:DOPerator
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(trigger=Trigger.Default, busFrameNull=BusFrameNull.Default, busFieldNull=BusFieldNull.Default) ConditionOperator[source]
# TRIGger<*>:USBThree:FRAMe<*>:FLD<*>:DOPerator
value: enums.ConditionOperator = driver.trigger.usbThree.frame.fld.doperator.get(trigger = repcap.Trigger.Default, busFrameNull = repcap.BusFrameNull.Default, busFieldNull = repcap.BusFieldNull.Default)

Sets the operator for the data pattern in the selected field of the selected frame.

Parameters:
  • trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

  • busFrameNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Frame’)

  • busFieldNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Fld’)

Returns:

data_operator: EQUal | NEQual | LTHan | LETHan | GTHan | GETHan | INRange | OORange

  • EQUal | NEQual | LTHan | LETHan | GTHan | GETHan: Equal, Not equal, Less than, Less than or equal, Greater than, Greater than or equal. These conditions require one endpoint value to be set using TRIGgert:USBThree:FRAMefr:FLDfl:DMIN.

  • INRange | OORange: In range, out of range. These conditions require a range of endpoint values to be set using TRIGgert:USBThree:FRAMefr:FLDfl:DMIN and TRIGgert:USBThree:FRAMefr:FLDfl:DMAX.

set(data_operator: ConditionOperator, trigger=Trigger.Default, busFrameNull=BusFrameNull.Default, busFieldNull=BusFieldNull.Default) None[source]
# TRIGger<*>:USBThree:FRAMe<*>:FLD<*>:DOPerator
driver.trigger.usbThree.frame.fld.doperator.set(data_operator = enums.ConditionOperator.EQUal, trigger = repcap.Trigger.Default, busFrameNull = repcap.BusFrameNull.Default, busFieldNull = repcap.BusFieldNull.Default)

Sets the operator for the data pattern in the selected field of the selected frame.

Parameters:
  • data_operator

    EQUal | NEQual | LTHan | LETHan | GTHan | GETHan | INRange | OORange

    • EQUal | NEQual | LTHan | LETHan | GTHan | GETHan: Equal, Not equal, Less than, Less than or equal, Greater than, Greater than or equal. These conditions require one endpoint value to be set using TRIGgert:USBThree:FRAMefr:FLDfl:DMIN.

    • INRange | OORange: In range, out of range. These conditions require a range of endpoint values to be set using TRIGgert:USBThree:FRAMefr:FLDfl:DMIN and TRIGgert:USBThree:FRAMefr:FLDfl:DMAX.

  • trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

  • busFrameNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Frame’)

  • busFieldNull – optional repeated capability selector. Default value: Nr0 (settable in the interface ‘Fld’)