Select

SCPI Command :

TRIGger<*>:SOURce[:SELect]
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(trigger=Trigger.Default) SourceDetailed[source]
# TRIGger<*>:SOURce[:SELect]
value: enums.SourceDetailed = driver.trigger.source.select.get(trigger = repcap.Trigger.Default)

Selects the source of the trigger signal.

Parameters:

trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

Returns:

source_detailed: CHAN1 | CHANnel1 | CHAN2 | CHANnel2 | CHAN3 | CHANnel3 | CHAN4 | CHANnel4 | EXTernanalog | SBUS | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15 | LOGIC | MSOB1 | MSOB2 | MSOB3 | MSOB4 | Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 | Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4 | DIFF1 | DIFF2 | COMMON1 | COMMON2 | LINE

  • CHAN1 = CHANnel1, CHAN2 = CHANnel2, CHAN3 = CHANnel3, CHAN4 = CHANnel4: Input channels

  • EXTernanalog: External analog signal connected to the External Trigger Input. For this source, only the analog edge trigger is available.

  • LINE: The instrument generates the trigger from the AC power input and synchronizes the signal to the AC power frequency.

  • SBUS: Serial bus

  • D0…D15: Digital channels (option R&S RTP-B1) See also: ‘Trigger settings for digital signals and parallel buses’

  • LOGIc: Logic combination of digital channels, used as trigger source (option R&S RTP-B1)

  • MSOB1 | MSOB2 | MSOB3 | MSOB4: Parallel bus (option R&S RTP-B1)

  • Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 | Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4: Input channels of R&S RT-ZVCmulti-channel power probe. Only available in the A-trigger with trigger type EDGE.

  • DIFF1 | DIFF2 | COMMON1 | COMMON2: Differential signals

set(source_detailed: SourceDetailed, trigger=Trigger.Default) None[source]
# TRIGger<*>:SOURce[:SELect]
driver.trigger.source.select.set(source_detailed = enums.SourceDetailed.CHAN1, trigger = repcap.Trigger.Default)

Selects the source of the trigger signal.

Parameters:
  • source_detailed

    CHAN1 | CHANnel1 | CHAN2 | CHANnel2 | CHAN3 | CHANnel3 | CHAN4 | CHANnel4 | EXTernanalog | SBUS | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15 | LOGIC | MSOB1 | MSOB2 | MSOB3 | MSOB4 | Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 | Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4 | DIFF1 | DIFF2 | COMMON1 | COMMON2 | LINE

    • CHAN1 = CHANnel1, CHAN2 = CHANnel2, CHAN3 = CHANnel3, CHAN4 = CHANnel4: Input channels

    • EXTernanalog: External analog signal connected to the External Trigger Input. For this source, only the analog edge trigger is available.

    • LINE: The instrument generates the trigger from the AC power input and synchronizes the signal to the AC power frequency.

    • SBUS: Serial bus

    • D0…D15: Digital channels (option R&S RTP-B1) See also: ‘Trigger settings for digital signals and parallel buses’

    • LOGIc: Logic combination of digital channels, used as trigger source (option R&S RTP-B1)

    • MSOB1 | MSOB2 | MSOB3 | MSOB4: Parallel bus (option R&S RTP-B1)

    • Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 | Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4: Input channels of R&S RT-ZVCmulti-channel power probe. Only available in the A-trigger with trigger type EDGE.

    • DIFF1 | DIFF2 | COMMON1 | COMMON2: Differential signals

  • trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)