Pcondition
SCPI Command :
TRIGger<*>:SERPattern:COMPlex:PATTern<*>:PCONdition
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(trigger=Trigger.Default, triggerPattern=TriggerPattern.Default) ConditionOperator[source]
# TRIGger<*>:SERPattern:COMPlex:PATTern<*>:PCONdition value: enums.ConditionOperator = driver.trigger.serPattern.complex.pattern.pcondition.get(trigger = repcap.Trigger.Default, triggerPattern = repcap.TriggerPattern.Default)
Sets the operator to define the exact position or range where the instrument looks for the specified pattern.
- Parameters:
trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)
triggerPattern – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pattern’)
- Returns:
operator: EQUal | NEQual | LTHan | LETHan | GTHan | GETHan | INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan: Equal, Not equal, Less than, Less or equal than, Greater Than, Greater or equal than. These operators require one identifier pattern to be set with TRIGgert:SERPattern:COMPlex:PATTernn:FRPTtern
INRange | OORange: In range / Out of range: Set the minimum and maximum value of the range with TRIGgert:SERPattern:COMPlex:PATTernn:FRPTtern and TRIGgert:SERPattern:COMPlex:PATTernn:TOPTtern.
- set(operator: ConditionOperator, trigger=Trigger.Default, triggerPattern=TriggerPattern.Default) None[source]
# TRIGger<*>:SERPattern:COMPlex:PATTern<*>:PCONdition driver.trigger.serPattern.complex.pattern.pcondition.set(operator = enums.ConditionOperator.EQUal, trigger = repcap.Trigger.Default, triggerPattern = repcap.TriggerPattern.Default)
Sets the operator to define the exact position or range where the instrument looks for the specified pattern.
- Parameters:
operator –
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan | INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan: Equal, Not equal, Less than, Less or equal than, Greater Than, Greater or equal than. These operators require one identifier pattern to be set with TRIGgert:SERPattern:COMPlex:PATTernn:FRPTtern
INRange | OORange: In range / Out of range: Set the minimum and maximum value of the range with TRIGgert:SERPattern:COMPlex:PATTernn:FRPTtern and TRIGgert:SERPattern:COMPlex:PATTernn:TOPTtern.
trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)
triggerPattern – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Pattern’)