PperiodError

SCPI Command :

TRIGger<*>:SENT:PPERioderror
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(trigger=Trigger.Default) bool[source]
# TRIGger<*>:SENT:PPERioderror
value: bool = driver.trigger.sent.pperiodError.get(trigger = repcap.Trigger.Default)

Triggers on pulse period errors. An error occurs when a nibble has any of the following:

  • number of ticks at low is less than 4 ticks.

  • nibble value < 0 (less than 12 ticks) or > 15 (more than 27 ticks) .

To trigger on an error event, select the correspondig trigger type with TRIGger<m>:SENT:TYPE ERRC.

Parameters:

trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

set(pls_period_err: bool, trigger=Trigger.Default) None[source]
# TRIGger<*>:SENT:PPERioderror
driver.trigger.sent.pperiodError.set(pls_period_err = False, trigger = repcap.Trigger.Default)

Triggers on pulse period errors. An error occurs when a nibble has any of the following:

  • number of ticks at low is less than 4 ticks.

  • nibble value < 0 (less than 12 ticks) or > 15 (more than 27 ticks) .

To trigger on an error event, select the correspondig trigger type with TRIGger<m>:SENT:TYPE ERRC.

Parameters:
  • pls_period_err – OFF | ON

  • trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)