TypePy
SCPI Command :
TRIGger<*>:PCIE:OSET:TYPE
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(trigger=Trigger.Default) OsetType[source]
# TRIGger<*>:PCIE:OSET:TYPE value: enums.OsetType = driver.trigger.pcie.oset.typePy.get(trigger = repcap.Trigger.Default)
Sets the ordered set to be triggered on.
- Parameters:
trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)
- set(ostype: OsetType, trigger=Trigger.Default) None[source]
# TRIGger<*>:PCIE:OSET:TYPE driver.trigger.pcie.oset.typePy.set(ostype = enums.OsetType.COMP, trigger = repcap.Trigger.Default)
Sets the ordered set to be triggered on.
- Parameters:
ostype –
SDSSKP: SKP ordered sets
TS1: Training sequence 1
TS2: Training sequence 2
FTS: Fast training sequence
EIOS: Electrical idle ordered set
EIEOS: Electrical idle exit ordered set
COMP: Compliance pattern
SDS: Start of data sequence
trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)