LccType
SCPI Command :
TRIGger<*>:MPHY:LCCType
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(trigger=Trigger.Default) LccType[source]
# TRIGger<*>:MPHY:LCCType value: enums.LccType = driver.trigger.mphy.lccType.get(trigger = repcap.Trigger.Default)
Selects the type of LCC frame to be triggered on.
- Parameters:
trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)
- Returns:
lcc_type: ANY | SLEEP | STALL | READCAP | READMFG | READVEND | WRITEATTR | PWMG0 | PWMG1 | PWMG2 | PWMG3 | PWMG4 | PWMG5 | PWMG6 | PWMG7 | HSG1A | HSG2A | HSG3A | HSG4A | HSG1B | HSG2B | HSG3B | HSG4B | RESERVED
ANY: All the available LCC commands.
SLEEP: Switches the power-saving state to ultra-low power. In this state, up to 90% power saving is achieved.
STALL: Switches the power-saving state to ultra-low power. In this state, up to 75% power saving is achieved.
READCAP: Recovers data about the OMC’s capabilities.
READMFG: Retrieves manufacturing ID and vendor-specific information.
READVEND: Retrieves the additional four delimited bytes containing vendor-specific information.
WRITEATTR: Sets the configuration parameters required for lane operation.
PWMG0 | PWMG1 | PWMG2 | PWMG3 | PWMG4 | PWMG5 | PWMG6 | PWMG7: Switches the transmission mode to the selected low-power gear.
HSG1A | HSG2A | HSG3A | HSG4A | HSG1B | HSG2B | HSG3B | HSG4B: Switches the transmission mode to the selected high-speed gear.
RESERVED: Reserved bit command. These bits are reserved for future use.
- set(lcc_type: LccType, trigger=Trigger.Default) None[source]
# TRIGger<*>:MPHY:LCCType driver.trigger.mphy.lccType.set(lcc_type = enums.LccType.ANY, trigger = repcap.Trigger.Default)
Selects the type of LCC frame to be triggered on.
- Parameters:
lcc_type –
ANY | SLEEP | STALL | READCAP | READMFG | READVEND | WRITEATTR | PWMG0 | PWMG1 | PWMG2 | PWMG3 | PWMG4 | PWMG5 | PWMG6 | PWMG7 | HSG1A | HSG2A | HSG3A | HSG4A | HSG1B | HSG2B | HSG3B | HSG4B | RESERVED
ANY: All the available LCC commands.
SLEEP: Switches the power-saving state to ultra-low power. In this state, up to 90% power saving is achieved.
STALL: Switches the power-saving state to ultra-low power. In this state, up to 75% power saving is achieved.
READCAP: Recovers data about the OMC’s capabilities.
READMFG: Retrieves manufacturing ID and vendor-specific information.
READVEND: Retrieves the additional four delimited bytes containing vendor-specific information.
WRITEATTR: Sets the configuration parameters required for lane operation.
PWMG0 | PWMG1 | PWMG2 | PWMG3 | PWMG4 | PWMG5 | PWMG6 | PWMG7: Switches the transmission mode to the selected low-power gear.
HSG1A | HSG2A | HSG3A | HSG4A | HSG1B | HSG2B | HSG3B | HSG4B: Switches the transmission mode to the selected high-speed gear.
RESERVED: Reserved bit command. These bits are reserved for future use.
trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)