Tr

SCPI Command :

TRIGger<*>:MILStd:CMD:TR
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(trigger=Trigger.Default) BusBitCondition[source]
# TRIGger<*>:MILStd:CMD:TR
value: enums.BusBitCondition = driver.trigger.milstd.cmd.tr.get(trigger = repcap.Trigger.Default)

Triggers on a transmission mode.

Parameters:

trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

Returns:

tr_flag: ONE | ZERO | DC

  • ONE: Transmit direction.

  • ZERO: Receive direction.

  • DC: Either directions.

set(tr_flag: BusBitCondition, trigger=Trigger.Default) None[source]
# TRIGger<*>:MILStd:CMD:TR
driver.trigger.milstd.cmd.tr.set(tr_flag = enums.BusBitCondition.DC, trigger = repcap.Trigger.Default)

Triggers on a transmission mode.

Parameters:
  • tr_flag

    ONE | ZERO | DC

    • ONE: Transmit direction.

    • ZERO: Receive direction.

    • DC: Either directions.

  • trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)