FrameType
SCPI Command :
TRIGger<*>:MDIO:FRAMetype
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(trigger=Trigger.Default) MdioFrameType[source]
# TRIGger<*>:MDIO:FRAMetype value: enums.MdioFrameType = driver.trigger.mdio.frameType.get(trigger = repcap.Trigger.Default)
Selects the Type of Frame code (or OP code, OpCode, operation code) ; available only in trigger type Data. Note that the same OpCode may have different meanings in Clause 22 and Clause 45.
- Parameters:
trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)
- Returns:
frame_type: OP00 | OP01 | OP10 | OP11 | OPXX
OP00: Address frame (in Clause 45, only)
OP01: Write frame (in Clause 22 or Clause 45)
OP10: Read frame (in Clause 22) or Post-Read increment address frame (in Clause 45)
OP11: Read frame (in Clause 45)
OPXX: Any frame type
- set(frame_type: MdioFrameType, trigger=Trigger.Default) None[source]
# TRIGger<*>:MDIO:FRAMetype driver.trigger.mdio.frameType.set(frame_type = enums.MdioFrameType.OP00, trigger = repcap.Trigger.Default)
Selects the Type of Frame code (or OP code, OpCode, operation code) ; available only in trigger type Data. Note that the same OpCode may have different meanings in Clause 22 and Clause 45.
- Parameters:
frame_type –
OP00 | OP01 | OP10 | OP11 | OPXX
OP00: Address frame (in Clause 45, only)
OP01: Write frame (in Clause 22 or Clause 45)
OP10: Read frame (in Clause 22) or Post-Read increment address frame (in Clause 45)
OP11: Read frame (in Clause 45)
OPXX: Any frame type
trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)