Cstep

SCPI Command :

TRIGger<*>:FLXRay:CSTep
Commands in total: 1
Subgroups: 0
Direct child commands: 1
get(trigger=Trigger.Default) int[source]
# TRIGger<*>:FLXRay:CSTep
value: int = driver.trigger.flxRay.cstep.get(trigger = repcap.Trigger.Default)

Specifies a step to trigger on each n-th cycle inside the given range. This allows for specific triggering if slot multiplexing is used. The condition method RsRtx.trigger.flxRay.cenable.set() must be set to INRange or OORange.

Parameters:

trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)

Returns:

cycle_count_step: 1 to 63

set(cycle_count_step: int, trigger=Trigger.Default) None[source]
# TRIGger<*>:FLXRay:CSTep
driver.trigger.flxRay.cstep.set(cycle_count_step = 1, trigger = repcap.Trigger.Default)

Specifies a step to trigger on each n-th cycle inside the given range. This allows for specific triggering if slot multiplexing is used. The condition method RsRtx.trigger.flxRay.cenable.set() must be set to INRange or OORange.

Parameters:
  • cycle_count_step – 1 to 63

  • trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)