TypePy
SCPI Command :
TRIGger<*>:CMSB:TYPE
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(trigger=Trigger.Default) BusCmsbType[source]
# TRIGger<*>:CMSB:TYPE value: enums.BusCmsbType = driver.trigger.cmsb.typePy.get(trigger = repcap.Trigger.Default)
Selects the trigger type for custom serial bus analysis.
- Parameters:
trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)
- Returns:
type_py: STARt | PATTern | ADVanced
STARt: Triggers on the frame start, which is the end of the gap time as specified in BUSb:CMSB:GAPTime:VALue
ADVanced: Advanced trigger with TRIGger:CMSB:ADVanced commands. Only available if frames are defined.
PATTern: Triggers on a data pattern to be specified in TRIGgert:CMSB:PATTern
- set(type_py: BusCmsbType, trigger=Trigger.Default) None[source]
# TRIGger<*>:CMSB:TYPE driver.trigger.cmsb.typePy.set(type_py = enums.BusCmsbType.ADVanced, trigger = repcap.Trigger.Default)
Selects the trigger type for custom serial bus analysis.
- Parameters:
type_py –
STARt | PATTern | ADVanced
STARt: Triggers on the frame start, which is the end of the gap time as specified in BUSb:CMSB:GAPTime:VALue
ADVanced: Advanced trigger with TRIGger:CMSB:ADVanced commands. Only available if frames are defined.
PATTern: Triggers on a data pattern to be specified in TRIGgert:CMSB:PATTern
trigger – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Trigger’)