SymbolRate
SCPI Command :
SIGNalconfig:SETup:SETTing<*>:SYMBolrate
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(setupSetting=SetupSetting.Default) float[source]
# SIGNalconfig:SETup:SETTing<*>:SYMBolrate value: float = driver.signalConfig.setup.setting.symbolRate.get(setupSetting = repcap.SetupSetting.Default)
Sets/ displays the symbol rate. Most standards have a pre-dfeind symbol rate, see Table ‘Technology and serial standard properties’.
- Parameters:
setupSetting – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Setting’)
- Returns:
symbol_rate: 100 to 40E+9
- set(symbol_rate: float, setupSetting=SetupSetting.Default) None[source]
# SIGNalconfig:SETup:SETTing<*>:SYMBolrate driver.signalConfig.setup.setting.symbolRate.set(symbol_rate = 1.0, setupSetting = repcap.SetupSetting.Default)
Sets/ displays the symbol rate. Most standards have a pre-dfeind symbol rate, see Table ‘Technology and serial standard properties’.
- Parameters:
symbol_rate – 100 to 40E+9
setupSetting – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Setting’)