Actual
SCPI Command :
POWer:SWITching:RESult:ENERgy:ACTual
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(meas_type: PwrSwitchingResultMeasType) float[source]
# POWer:SWITching:RESult:ENERgy:ACTual value: float = driver.power.switching.result.energy.actual.get(meas_type = enums.PwrSwitchingResultMeasType.CON)
Return the specified statistic result of the specified measurement type. The command affects the content of export files as well as data retrieved with:
[:ACTual]: current measurement result
AVG: average of the long-term measurement results
EVTCount: number of measurement results in the long-term measurement
NPEak: negative peak value of the long-term measurement results
PPEak: positive peak value of the long-term measurement results
RMS: RMS value of the long-term measurement results
STDDev: standard deviation of the long-term measurement results
- Parameters:
meas_type – SWF: Switching frequency TON: Turn on TOF: Turn off CON: conduction NCO: Non conduction TOT: Total
- Returns:
value: Statistic result