Base
SCPI Command :
ADVJitter<*>:RESult:PAMJitter:CONFig:CATegory<*>:MEASurement<*>:BASE
- Commands in total: 1Subgroups: 0Direct child commands: 1
- get(advJitter=AdvJitter.Default, category=Category.Default, measurement=Measurement.Default) PamLevel[source]
# ADVJitter<*>:RESult:PAMJitter:CONFig:CATegory<*>:MEASurement<*>:BASE value: enums.PamLevel = driver.advJitter.result.pamJitter.config.category.measurement.base.get(advJitter = repcap.AdvJitter.Default, category = repcap.Category.Default, measurement = repcap.Measurement.Default)
Selects the base level. This is the lowest amplitude level used in the modulation. It sets the reference point for the least amount of energy a pulse can carry in the system.
- Parameters:
advJitter – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘AdvJitter’)
category – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Category’)
measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)
- Returns:
base_level: LEVEL0 | LEVEL1 | LEVEL2 | LEVEL3 | LEVEL4 | LEVEL5 | LEVEL6 | LEVEL7
- set(base_level: PamLevel, advJitter=AdvJitter.Default, category=Category.Default, measurement=Measurement.Default) None[source]
# ADVJitter<*>:RESult:PAMJitter:CONFig:CATegory<*>:MEASurement<*>:BASE driver.advJitter.result.pamJitter.config.category.measurement.base.set(base_level = enums.PamLevel.LEVEL0, advJitter = repcap.AdvJitter.Default, category = repcap.Category.Default, measurement = repcap.Measurement.Default)
Selects the base level. This is the lowest amplitude level used in the modulation. It sets the reference point for the least amount of energy a pulse can carry in the system.
- Parameters:
base_level – LEVEL0 | LEVEL1 | LEVEL2 | LEVEL3 | LEVEL4 | LEVEL5 | LEVEL6 | LEVEL7
advJitter – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘AdvJitter’)
category – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Category’)
measurement – optional repeated capability selector. Default value: Nr1 (settable in the interface ‘Measurement’)