Source code for rsrtx.Implementations.Measurement.Emc.Limit.Selection

from .....Internal.Core import Core
from .....Internal.CommandsGroup import CommandsGroup
from .....Internal import Conversions
from ..... import enums
from ..... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class SelectionCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("selection", core, parent)

[docs] def set(self, limits_standard: enums.EmcLimitsStandard, measurement=repcap.Measurement.Default) -> None: """ ``MEASurement<*>:EMC:LIMit:SELection`` \n Snippet: ``driver.measurement.emc.limit.selection.set(limits_standard = enums.EmcLimitsStandard.AD1, measurement = repcap.Measurement.Default)`` \n Selects the electrostatic discharge (ESD) immunity test levels according to the guidelines of the EN IEC 61000-4-2:2025 standard. For contact discharge (CD) and air discharge (AD) , it specifies the maximum voltage (kV) . \n - CD1: Contact discharge, 2 kV. - CD2: Contact discharge, 4 kV. - CD3: Contact discharge, 6 kV. - CD4: Contact discharge, 8 kV. - AD1: Air discharge, 2 kV. - AD2: Air discharge, 4 kV. - AD3: Air discharge, 8 kV. - AD4: Air discharge, 15 kV. :param limits_standard: CD1 | CD2 | CD3 | CD4 | AD1 | AD2 | AD3 | AD4 :param measurement: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Measurement') """ param = Conversions.enum_scalar_to_str(limits_standard, enums.EmcLimitsStandard) measurement_cmd_val = self._cmd_group.get_repcap_cmd_value(measurement, repcap.Measurement) self._core.io.write_with_opc(f'MEASurement{measurement_cmd_val}:EMC:LIMit:SELection {param}')
# noinspection PyTypeChecker
[docs] def get(self, measurement=repcap.Measurement.Default) -> enums.EmcLimitsStandard: """ ``MEASurement<*>:EMC:LIMit:SELection`` \n Snippet: ``value: enums.EmcLimitsStandard = driver.measurement.emc.limit.selection.get(measurement = repcap.Measurement.Default)`` \n Selects the electrostatic discharge (ESD) immunity test levels according to the guidelines of the EN IEC 61000-4-2:2025 standard. For contact discharge (CD) and air discharge (AD) , it specifies the maximum voltage (kV) . \n - CD1: Contact discharge, 2 kV. - CD2: Contact discharge, 4 kV. - CD3: Contact discharge, 6 kV. - CD4: Contact discharge, 8 kV. - AD1: Air discharge, 2 kV. - AD2: Air discharge, 4 kV. - AD3: Air discharge, 8 kV. - AD4: Air discharge, 15 kV. :param measurement: optional repeated capability selector. Default value: Nr1 (settable in the interface 'Measurement') :return: limits_standard: CD1 | CD2 | CD3 | CD4 | AD1 | AD2 | AD3 | AD4 """ measurement_cmd_val = self._cmd_group.get_repcap_cmd_value(measurement, repcap.Measurement) response = self._core.io.query_str_with_opc(f'MEASurement{measurement_cmd_val}:EMC:LIMit:SELection?') return Conversions.str_to_scalar_enum(response, enums.EmcLimitsStandard)