Source code for rsrtx.Implementations.Channel.Aafpermanent

from ...Internal.Core import Core
from ...Internal.CommandsGroup import CommandsGroup
from ...Internal import Conversions
from ... import enums
from ... import repcap


# noinspection PyPep8Naming,PyAttributeOutsideInit,SpellCheckingInspection
class AafpermanentCls:
	"""
	| Commands in total: 1
	| Subgroups: 0
	| Direct child commands: 1
	"""

	def __init__(self, core: Core, parent):
		self._core = core
		self._cmd_group = CommandsGroup("aafpermanent", core, parent)

[docs] def set(self, bandwidt_antialiasing: enums.BwAntialiasing, channel=repcap.Channel.Default) -> None: """ ``CHANnel<*>:AAFPermanent`` \n Snippet: ``driver.channel.aafpermanent.set(bandwidt_antialiasing = enums.BwAntialiasing.DEFault, channel = repcap.Channel.Default)`` \n Activates the anti-aliasing filter. The filter removes spurious and undersampled components of the signal and thus provides additional bandwidth limitation. The command is available for R&S RTO6 oscilloscope with 6 GHz bandwidth. Filter setting is only possible in remote control. :param bandwidt_antialiasing: DEFault | ON | OFF \n - DEFault: Automatic usage of the filter in non-interleaved mode. - ON: Filter is active also in interleaved mode. - OFF: Filter is ignored. :param channel: optional repeated capability selector. Default value: Ch1 (settable in the interface 'Channel') """ param = Conversions.enum_scalar_to_str(bandwidt_antialiasing, enums.BwAntialiasing) channel_cmd_val = self._cmd_group.get_repcap_cmd_value(channel, repcap.Channel) self._core.io.write_with_opc(f'CHANnel{channel_cmd_val}:AAFPermanent {param}')
# noinspection PyTypeChecker
[docs] def get(self, channel=repcap.Channel.Default) -> enums.BwAntialiasing: """ ``CHANnel<*>:AAFPermanent`` \n Snippet: ``value: enums.BwAntialiasing = driver.channel.aafpermanent.get(channel = repcap.Channel.Default)`` \n Activates the anti-aliasing filter. The filter removes spurious and undersampled components of the signal and thus provides additional bandwidth limitation. The command is available for R&S RTO6 oscilloscope with 6 GHz bandwidth. Filter setting is only possible in remote control. :param channel: optional repeated capability selector. Default value: Ch1 (settable in the interface 'Channel') """ channel_cmd_val = self._cmd_group.get_repcap_cmd_value(channel, repcap.Channel) response = self._core.io.query_str_with_opc(f'CHANnel{channel_cmd_val}:AAFPermanent?') return Conversions.str_to_scalar_enum(response, enums.BwAntialiasing)